Wednesday, December 15, 2010
Automatically turn off the gas water heater water heater common cause failure analysis.
User support has reflected <p> using a gas water heater at home, the original use has been normal, you can always use a moment when proximal to turn off the engine off the water, the resort to fire to fire, but soon the fire went out, and very .headache. .Xiaobian to an analysis for the extinction of domestic gas water heater the cause? .</ P> <p> gas water heater is controlled by air control solenoid valve, electronic ignition. .Automatically turn off after opening two minutes and could not beat the cause of the fire because most of the electromagnetic valve control module is damaged, replacement can continue to use after. .Another: Most water heaters set protection time, only for 20 minutes, turn off automatically after 20 minutes. .</ P> <P> <P> <p> gas water heaters automatically turn off the reason </ p> <p> a water heater with a long time, the internal joints loose, tightening, or for a new on it; .</ p> <p> Second, if you use more than two years, the induction heater may also be a problem with needles, conductive function properly, so it must be renewed; </ p> <p> three bad ignition ., the ignition water heater due to the natural reaction after the fire, but about a few seconds because the heat sensors will put out enough for it to replace the ignition. .</ P> <p> four solenoid valve bad. .</ P> <p> V, the battery is dead, the battery must be replaced; </ p> <p> six low water pressure, you can try a different time to open water heaters. .</ P> <p> seven, sometimes the wind will exhaust pipe intrusion have this phenomenon, you can simply installing hood in the exhaust port can solve the problem. .</ P> <p> flame gas water heater repair maintenance treatment </ p> <p> set fire gas water heater has two main effects: First, it ignited the main burner; second is the use of its thermoelectric .Even non-stop heating. .Thermocouple is a heat energy into electrical energy can be a component installed in the fire side, the heat generated by current control solenoid valve, open fire in the supply channel to achieve the maintenance of gas, the purpose of continuing the fire ignited. .Water heater used for a period of time, prone to fire and flame failure can not be sustained. .Its causes and treatment methods are as follows: </ p> <p> fire's air supply channel unreasonable or can not maintain the root cause of a malfunction turn. .If the thermocouple or the solenoid valve failure, or fire nozzle clogging, can cause gas supply channel barrier. .When the thermocouple down performance, even if the burn is red, when the hand let go after the ignition was still no fire, but also hear the voice of solenoid valve operation. .In addition to thermocouple failure, the presence of cracks or loose electrode leads are not sustained fault may cause ignition. .If the hands release the fire could be seen, but can hear the voice of the electromagnetic release valve, it is the nozzle clogging, when the fire's air supply can be removed with a thin copper wire at dirt can be blocked off by disclosing. .If the fire after hand release, but soon after goes off, it is caused by the thermocouple. .Can try to re-adjust its best heated location, the general will be able to troubleshoot. .</ P> <p> maintenance thermocouple may be artificially heated, if heated to produce current, coupled with solenoid valves, heating and press the stem pull a good time, indicating that the thermocouple well. .To replace the water heater, in case of fire ignited heated side of the heated thermocouple adjusted position. .By up, down, left and right several adjustments, when the fire in the Waiyan and with sufficient heating area, the fire will normally be retained. .</ P>.
Labels:
[:]
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment